The Moisture Test That Decides Your Floor
Two tests decide whether your floor lasts. ASTM F1869 is the calcium chloride dish, measuring pounds of moisture per 1,000 square feet per 24 hours. ASTM F2170 is a relative humidity probe drilled into the slab. Both take 72 hours, and the result picks the primer before anyone picks a colour.

If nobody has mentioned either of these to you, nobody knows what your slab is doing.
Why does a slab have moisture in it at all?
Two sources. Concrete poured with more water than the cement needs keeps releasing the excess for months, sometimes years. And a slab in contact with the ground draws moisture up through itself by capillary action, continuously, for as long as it exists.
A vapour barrier under the slab is supposed to stop the second one. Plenty of Kansas City basements poured before the 1980s do not have one, or have one that was punctured during the pour, and that is a large share of the lower levels in the older parts of this metro.
What does each test actually measure?
| ASTM F1869 | ASTM F2170 | ASTM D4263 | |
|---|---|---|---|
| Common name | Calcium chloride | In-situ relative humidity | Plastic sheet |
| What it reads | Surface emission rate | Humidity inside the slab | Presence, not amount |
| How | Salt dish under a sealed dome | Probe in a drilled hole | Taped plastic square |
| Time needed | 72 hours | 72 hours | 24 hours |
| Gives a number | Yes, lbs per 1,000 sq ft | Yes, percent RH | No |
| Accepted by manufacturers | Yes | Yes, preferred | No |
The important distinction is depth. The calcium chloride test reads what is coming off the surface right now. The relative humidity probe reads what the slab is holding at 40 percent of its depth, which is what will eventually reach the surface once you seal it.
That matters because a coating changes the slab. An uncoated floor is breathing, so the surface reads dry. Seal it, and the moisture that was evaporating has nowhere to go but up against the back of your new coating.
What do the numbers mean?
Most resin manufacturers set their limit around 3 pounds on the calcium chloride test and 75 to 80 percent on the relative humidity probe. Above that, a standard primer is outside its specification and the system has to change.
| Reading | What it means | What changes |
|---|---|---|
| Under 3 lbs / under 75 percent RH | Normal | Standard primer, standard price |
| 3 to 5 lbs / 75 to 85 percent RH | Elevated | Moisture mitigation primer, adds $1 to $2 per sq ft |
| Over 5 lbs / over 85 percent RH | High | Mitigation system, and the source needs investigating first |
What happens if the test comes back high?
A moisture mitigation primer, which is a different, denser product that forms a barrier rather than simply bonding. It adds roughly $1 to $2 per square foot, and on a basement it is the single most common reason a quote moves after the site visit.
It is not optional at that point. I have watched people ask whether we can skip it and take the chance, and the answer is no, because the failure mode is not cosmetic. Moisture pushing up behind a sealed coating lifts it in blisters, and a blistered floor has to be ground off entirely.
Can I test it myself?
Roughly, yes. Tape a two foot square of clear plastic sheet tightly to the slab on all four sides and leave it 24 hours. If there is condensation on the underside, or the concrete beneath it has gone visibly darker, the slab is moving moisture.
That is the ASTM D4263 plastic sheet test and it is a screening tool rather than a measurement. It tells you whether to worry. It does not give a number, and no manufacturer will accept it as justification for a system choice.
Why does everyone skip this?
Because it takes 72 hours and it can lose you the job. An installer who tests properly has to come back three days later, and sometimes has to go back to the customer with a higher number than the one they quoted. An installer who skips it quotes lower, wins the work, and is not there in two years when it blisters.
Here is my honest position and plenty in this trade would disagree. On a slab on grade in this metro I would rather lose the job than coat it untested. We have turned down work over this, and the two floors we did test-and-walk-away from both belonged to people who had already had one coating fail.
The basement flooring page covers why this matters most below grade. Why two quotes differ has the other questions to ask, and the about page has the full four step build.
What to do next
The test is part of the free estimate, not an extra line. Send the space through the form on this page and Glen calls you back, usually the same working day. He measures on site before anything is final, so the number you get is fixed rather than a range. Or call 816-500-1161, Monday to Friday 7am to 6pm.
Tell us the space. We will price it.
Four questions about the floor, then your details. Glen reads every one of these himself and comes out to measure before anything is final.
- Free, no obligation estimate
- Measured on site, not guessed
- Residential and commercial
- Missouri and Kansas
-
01
You send the space
Type, rough size and what it is used for.
-
02
Glen calls back
Usually the same working day, from the number below.
-
03
He measures on site
Then you get a fixed price, not a range.
Would rather talk it through? Call 816-500-1161, Monday to Friday 7am to 6pm.
Request a Quote
Takes about a minute.